Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38492813

RESUMO

PURPOSE: Craniopharyngiomas (CPs) are rare tumors of the sellar region often leading to significant comorbidities due to their close proximity to critical structures. The aim of this study was to analyze survival outcome and late toxicities after surgery and proton beam therapy (PBT) in childhood CPs. METHODS AND MATERIALS: Within the prospective registry study "KiProReg" (DRKS0000536), data of 74 childhood patients with CP, receiving PBT between August 2013 to June 2022 were eligible. Late toxicities were analyzed according to the grading system of the Common Terminology Criteria for Adverse Events, version 4.0. RESULTS: Median follow-up since first diagnosis was 4.3 years (range, 0.8-14.7). In addition, 75.7% of patients received PBT at time of disease progression or recurrence, whereas 24.3% as part of their primary therapy (definitive or adjuvant). Predominantly (85.1%), pencil beam scanning technique was used. The median total dose and initial tumor volume were 5400 cGy relative biologic effectiveness (RBE) and 17.64 cm³ (range, 3.07-300.59), respectively. The estimated (±SE) 3-year overall survival, progression-free, and cystic failure-free survival rate after PBT were 98.2% (±1.7), 94.7% (±3.0), and 76.8% (±5.4), respectively. All local failures (n = 3) were in-field relapses necessitating intervention and occurred exclusively in patients receiving PBT at progression or recurrence. Early cystic enlargements after PBT were typically asymptomatic and self-limiting. Fatigue, headaches, vision disorders, obesity, and endocrinopathies were the predominant late toxicities. No high-grade (≥3) new-onset visual impairment or cognitive deterioration occurred compared with baseline. The presence of cognitive impairments at the end of follow-up correlated with size of the planning target volume (P = .034), Dmean dose to the temporal lobes (P = .032, P = .045) and the number of surgical interventions before PBT (P = .029). CONCLUSIONS: Our findings demonstrate favorable local control rates using modern PBT with acceptable late toxicities. Cyst growth within 12 months after radiation therapy is typically not associated with tumor progression. Longer follow-up must be awaited to confirm results.

2.
Phys Eng Sci Med ; 46(3): 1287-1295, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37405636

RESUMO

To dosimetrically compare applicator-guided intensity-modulated proton therapy (IMPT) and multichannel brachytherapy (MC-BRT) for vaginal vault irradiation (VVI) with special focus on dose to organs at risk (OARs) and normal tissues. Ten patients with uterine confined endometrial cancer who received adjuvant vaginal cuff brachytherapy were included in this study. For each patient an additional IMPT treatment plan was created using the same computed tomography dataset and contours segmented for MC-BRT plans. Clinical target volume (CTV) was defined as the proximal 3.5 cm of the vagina including the entire thickness of vaginal wall. Planning target volume for IMPT plans was generated from the CTV with an addition isotropic 3 mm margin. OARs included rectum, bladder, sigmoid, small bowel and femoral heads. The prescribed dose was 21 Gy in 3 fractions. For simplicity, all doses were expressed in Gy and a constant relative biological effectiveness of 1.1 was used for IMPT plans. Plan comparison was performed using dose-volume histogram and treatment planning parameters. A significant improvement of the D98% coverage for CTV was reached by the applicator-guided IMPT plans (p < 0.01). IMPT also provided a dose reduction in all OARs except for femoral heads due to the lateral beam direction, especially significant reduction of V5Gy, D2cc, D0.1 cc, Dmean, V95% values for the rectum and Dmean, D0.1 cc to bladder, sigmoid, small bowel. Additionally, IMPT plans showed a significant reduction of integral dose to normal tissue with respect to MC-BRT (221.5 cGy.L vs. 653.6 cGy.L, p < 0.01). Applicator-guided IMPT has the potential for improving plan quality in VVI while maintaining the high conformity afforded by the state-of-the-art intracavitary brachytherapy.


Assuntos
Neoplasias do Endométrio , Doses de Radiação , Neoplasias do Endométrio/terapia , Terapia com Prótons/métodos , Braquiterapia/métodos , Humanos , Feminino , Vagina
3.
Front Oncol ; 11: 599018, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34055596

RESUMO

Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more. This hampers the sparing of organs-at-risk if small-scale structures adjacent to the target volume are concerned. The trimming of spot scanning fields with collimating apertures constitutes a simple measure to increase the transversal dose gradient. The current study describes the clinical implementation of brass apertures in conjunction with the pencil-beam scanning delivery mode at a horizontal, clinical treatment head based on commercial hardware and software components. Furthermore, clinical cases, which comprised craniopharyngiomas, re-irradiations and ocular tumors, were evaluated. The dosimetric benefits of 31 treatment plans using apertures were compared to the corresponding plans without aperture. Furthermore, an overview of the radiation protection aspects is given. Regarding the results, robust optimization considering range and setup uncertainties was combined with apertures. The treatment plan optimizations followed a single-field uniform dose or a restricted multi-field optimization approach. Robustness evaluation was expanded to account for possible deviations of the center of the pencil-beam delivery and the mechanical center of the aperture holder. Supplementary apertures improved the conformity index on average by 15.3%. The volume of the dose gradient surrounding the PTV (evaluated between 80 and 20% dose levels) was decreased on average by 17.6%. The mean dose of the hippocampi could be reduced on average by 2.9 GyRBE. In particular cases the apertures facilitated a sparing of an organ-at-risk, e.g. the eye lens or the brainstem. For six craniopharyngioma cases the inclusion of apertures led to a reduction of the mean dose of 1.5 GyRBE (13%) for the brain and 3.1 GyRBE (16%) for the hippocampi.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...